DORIT-11S2
20 Degree Straight Head Low Speed Handpiece
ISO standard E-type connection
Availability: | |
---|---|
1.Water/air channel isolation. Still keep perfect performance in instable air pressure and water pressure situation.
2. Easy operation, Harm-free, Reduce pain during treatment
3. Perfect atomization and cooling uniformity, no droplet out from mouth in use .clean hygiene.
4. Integrate sterilization make it clean simple and convenient.
5. Made from 303 stainless steel (imported from Japan), Durable, Dirt free
1.Water/air channel isolation. Still keep perfect performance in instable air pressure and water pressure situation.
2. Easy operation, Harm-free, Reduce pain during treatment
3. Perfect atomization and cooling uniformity, no droplet out from mouth in use .clean hygiene.
4. Integrate sterilization make it clean simple and convenient.
5. Made from 303 stainless steel (imported from Japan), Durable, Dirt free
Air pressure | 245-392kpa |
Water pressure | 200Kpa |
Atomized air pressure | 200Kpa |
Rotation speed | 14,000~20,000rpm |
Bur taking | Turn the sleeve to take burs (counterclockwise 100° ) |
Bur applicable | Φ2.33~2.35mm |
Noise | ≤70DB |
Voltage | 3.0V~3.2V |
Air pressure | 245-392kpa |
Water pressure | 200Kpa |
Atomized air pressure | 200Kpa |
Rotation speed | 14,000~20,000rpm |
Bur taking | Turn the sleeve to take burs (counterclockwise 100° ) |
Bur applicable | Φ2.33~2.35mm |
Noise | ≤70DB |
Voltage | 3.0V~3.2V |
Chuck | The chuck must be applicable bur corresponding to IOS 1797-2Norms |
Water and chip air supply | When air pressure is at 200kPa,water flow rate is not less than 50ML/min and air flow rate not less than 1.5L/min |
Connector of handpiece | The structure, measurement and tolerance of back end of handpiece conform with YY1012 Norm. |
Sterilization | Handpiece endure sterilization temperature at least 136℃ about 12 minutes once, for 250 times reuse without damage. |
Temperature test | Under normal working conditions, the connected surface temperature rises less than 22℃ over ambient temperature. |
Corrosion | There is no corrosion appearance after sterilization cycle. |
Illumination electricity supply safety | Conforming with GB 9706.1-2007 Norm . |
Chuck | The chuck must be applicable bur corresponding to IOS 1797-2Norms |
Water and chip air supply | When air pressure is at 200kPa,water flow rate is not less than 50ML/min and air flow rate not less than 1.5L/min |
Connector of handpiece | The structure, measurement and tolerance of back end of handpiece conform with YY1012 Norm. |
Sterilization | Handpiece endure sterilization temperature at least 136℃ about 12 minutes once, for 250 times reuse without damage. |
Temperature test | Under normal working conditions, the connected surface temperature rises less than 22℃ over ambient temperature. |
Corrosion | There is no corrosion appearance after sterilization cycle. |
Illumination electricity supply safety | Conforming with GB 9706.1-2007 Norm . |